China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier
China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier China JYWQ Type Self-Mixing Automatic Sewage Pump - China Supplier

JYWQ Type Self-Mixing Automatic Sewage Pump

Price:888.00
Industry Category: Machinery
Product Category:
Brand: 上海三利泵业(集团)有限公司
Spec: 上海三利泵业(集团)有限公司


Contact Info
  • Add:万祥镇, Zip: 200000
  • Contact: 叶志通
  • Tel:18590330992
  • Email:

Other Products

Description
Additional Information

Without a good water pump, water usage becomes a major hassle. Have these issues been troubling you as well?

Selected by the design unit, our company's Sewage Pump|Submersible Pump Series, please order directly from the sanli sales department by model. For important usage occasions or complex environments, please try to provide design drawings and detailed parameters for our review and approval.


Introduction to JYWQ Type Automatic Stirring Sewage Pump

Our produced JYWQ type automatic stirring sewage pump product features anti-sediment stirring technology that generates high-speed vortices around the pump and at the pool bottom, preventing debris from settling and allowing it to be drawn into the pump and discharged. It achieves the stirring function without rotating parts, and the channels for stirring high-pressure water are equipped with multiple special filtration devices for impurities, ensuring no clogging and maintaining stirring effectiveness. It also solves the problem of the rotor being entangled by fibrous rope-like materials during pump operation, which can burn out the motor.

To prevent sediment from accumulating at the bottom of the pool and avoid the need for cleaning, the industry currently employs two types of stirring functions in pumps:

1. A small auxiliary impeller is installed below the main pump impeller. The pressure generated by this auxiliary impeller does not effectively stir debris; instead, it consumes the pump motor's power and is prone to tangling debris around the impeller.

2. A hole is drilled at the center of the impeller blocking the rotor shaft, with a T-shaped stirring head installed below. Pressure water from the pump cavity is sprayed around the sewage pool through the central hole of the shaft and the stirring head. This structure can lead to clogging of the water flow holes by sewage impurities, resulting in no stirring effect, and the stirring head can become entangled by fibrous rope-like materials during rotation, burning out the motor.

Three additional flushing water pipes are installed under the pump base. The stirring function relies on the water pressure delivered by the automatic stirring sewage pump to flush and stir the sediment around the pump, suspending it before it is discharged by the sewage pump, without affecting flow rate or head.


Structure and Features of JYWQ Type Automatic Stirring Sewage Pump


1

Main Cable

8

Base

2

Housing

9

Partition

3

Internal Circulation Sleeve

10

Control Cable

4

Oil Chamber

11

Oil Head Probe

5

Auxiliary Impeller

12

Mechanical Seal

6

Impeller

13

Stirring Component

7

Pump Body

1. Utilizes a dual-channel non-clogging impeller structure to enhance the flow and discharge capabilities for sewage and debris.

2. Automatic stirring device generates strong stirring force, suspending sediment in the pool before drawing it into the impeller for discharge, achieving dredging effects.

3. Partition divides the base into two sections, ensuring stirring and water intake do not interfere with each other.

4. Mechanical seal is a double-end mechanical seal, long-term immersed in the oil chamber for reliable pump operation.

5. The auxiliary impeller structure provides hydrodynamic sealing, offering auxiliary sealing to protect the mechanical seal, while balancing axial forces to extend bearing life.

6. The pump connection chamber includes a water leakage detection probe; upon leakage, the probe signals the control system to protect the pump. Our company can provide fully automatic protection control cabinets.

7. Motor stator uses Class B and F insulation, with built-in thermal protectors that activate upon motor overload or overheating, providing comprehensive protection for the pump and motor.

8. Oil chamber is equipped with an oil-water probe; if the mechanical seal fails and water enters the oil chamber, the probe signals the control system to protect the pump.

9. Features an internal circulation cooling system, allowing the pump to operate normally at low water levels in the pool.


Installation Diagram of JYWQ Type Automatic Stirring Sewage Pump


1

Ventilation Section

11

Automatic Stirring Sewage Pump

2

Embedded Pipe

12

Float Switch

3

Expansion Joint

13

Partition

4

Check Valve

14

Float Bracket

5

Gate Valve

15

Small Chain

6

Elbow Pipe

16

Hook

7

Guide Rail

17

Ladder

8

Discharge Pipe

18

Support Bracket

9

Bracket

19

Cable Outlet

10

Coupling Base

20

Motor Protection


Installation Plan of JYWQ Type Automatic Stirring Sewage Pump


Dual Rail Dual Pump Drainage Plan


Single Rail Single Pump Drainage Plan

Note:When selecting JYWQ and JPWQ series automatic stirring submersible sewage pumps,

please specify the pump model, installation method, pool depth, and pump control protection method to ensure a reliable system.


Applications of JYWQ Type Automatic Stirring Sewage Pump

1. Discharge of industrial and commercial polluted wastewater.

2. Drainage systems in urban sewage treatment plants.

3. Sewage drainage stations in residential areas.

4. Drainage stations in civil air defense systems, water supply devices in water plants.

5. Municipal engineering and construction sites.

6. Supporting equipment for exploration, mining, and power plants.

7. Rural ponds, farmland irrigation, and pond dredging.


-Quality products pay attention to details, ensuring your purchase is worry-free!

-Ample inventory to prevent delivery delays!!

Note: All text, data, and images in this article are for reference only. For more detailed parameters, selection, and pricing of JYWQ type automatic stirring sewage pump, please contact us. 「sanli is dedicated to providing you with answers.


Precautions for JYWQ Type Automatic Stirring Sewage Pump

(1) Before operation, use a megohmmeter to check the insulation resistance of the motor stator winding to ground; it must not be less than 50 megohms.

(2) Check the cable for damage or breakage. Replace if damaged to prevent electric leakage; the cable cross-section should match the current.

(3) Do not start the pump if the voltage exceeds ±10% of the rated voltage.

(4) Always ground the earth wire in the four-core cable during use to prevent electric shock accidents.

(5) When submerging the pump, lift it vertically; do not place it horizontally on the ground or allow it to sink into sludge. After use, lift and clean the pump, store it in a dry place, and protect it from freezing.

(6) Do not use the cable as a lifting rope.

(7) Check the rotor rotation direction; viewed from above, it should rotate clockwise.

(8) Outdoor switches or terminals should have rain and moisture protection. Do not touch the switch with wet hands or bare feet to prevent electric shock.

(9) When moving the pump, cut off the power. Do not contact water sources while the pump is running to avoid electric shock accidents.

(10) Do not operate the motor with a missing phase. If a fuse blows, check the cause before continuing; do not arbitrarily use thicker fuses.

(11) During operation, have专人 manage the pump. If any abnormality is detected, stop immediately for inspection and troubleshooting. (Applies when not equipped with a fully automatic protection cabinet)

(12) After six months of normal operation under specified conditions, check the oil chamber seal. If the oil appears milky or has water沉淀, replace it promptly.

(13) Users should select the appropriate flow rate and head based on actual conditions for optimal performance. The parameters on the pump nameplate or manual are for standard conditions; users can operate within (0.7 to 1.2) times the flow rate. Do not exceed the flow rate, as excessive flow and low head can easily cause motor overload.


Maintenance of JYWQ Type Automatic Stirring Sewage Pump

■ The pump should be managed and used by designated personnel, with regular checks on the insulation resistance between the motor winding and housing.

■ After each use with thick or viscous media, run the pump in clean water for several minutes to prevent internal sediment buildup and maintain pump cleanliness.

■ After disassembly or repair, the housing components must undergo a 0.2MPa气压 pressure test to ensure the integrity of the motor and oil chamber seals.

Looking forward to a bright future, "Adhering to technology, meticulously crafting products, and wholeheartedly serving customers" is 「sanli's quality policy. We are committed to contributing to the advancement of the national industry with an innovative spirit. We warmly welcome collaboration with merchants nationwide to contribute to national construction.



Industry Category Machinery
Product Category
Brand: 上海三利泵业(集团)有限公司
Spec: 上海三利泵业(集团)有限公司
Stock:
Origin: China / Shanghai / Pudongxinqu
About Toocle.com - Partner Programme - Old Version
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192